Olympus CF-HQ190L EVIS EXERA III Video Colonoscope
$9,876.00$14,567.00
The CF-HQ190L has HDTV resolution and Narrow Band Imaging (NBI) technology. This improves mucosal detail and reveals vascular patterns more clearly.
It helps in detecting lesions more accurately. Its ergonomic design and flexible insertion tube improve maneuverability while maintaining patient comfort. It offers reliability, precision, and performance. These features help achieve better results in modern endoscopy.
Only 1 left in stock
Description
The EVIS EXERA III CF-HQ190L/I//colonovideoscope features a special Dual Focus optical system. It also features Narrow Band Imaging (NBI) to produce clear, bright images for enhanced viewing. Unique Responsive Insertion Technology (RIT) ensures ease of insertion and excellent scope handling during a complete colonoscopy.
The Olympus CF-HQ190L EVIS EXERA III Video Colonoscope offers a range of viewing options. It has a wide field of view and high image quality. Featuring a ScopeGuide for 3D visualization and Narrow Band Imaging, it provides detailed insights into colon conditions.
This colonoscope has dual focus selection for precise examination depths. It also features a waterproof one-touch connector for secure connections. This makes it a versatile and reliable tool for medical professionals.
Key Benefits
- Get the best depth of field with just a button. Dual Focus, an Olympus innovation, lets you choose between two focus settings. This helps you achieve the right depth of field for better observation.
- Brighter and stronger imaging: Narrow Band Imaging (NBI) now offers much more brightness. It gives you twice the viewable distance compared to older scope models.
- Smoother and more comfortable insertions: Responsive Insertion Technology (RIT) uses three special tube technologies. This helps make colonoscopies easier by improving the handling and insertion of the scope.
- Easier setup: A new waterproof connector design makes setup easier before and between cases. It also removes the need for a water-resistant cap.
Key Features:
- Delivers the highest possible resolution and image quality
- Widest field of view available in a colonoscope, 170 degrees
- Olympus-exclusive variable stiffness capability
- 3 light guides for improved lighting
- Auxiliary water jet facilitates mucosal cleansing
- Ergonomically designed grip to enhance scope maneuverability and handling
- Scope ID function stores individual scope information, such as the number of procedures performed
- The benefit of Narrow Band Imaging (NBI) is to enhance the visualization of mucosal morphology
- Must be used with Exera III CV190 processor and CLV-190 light source
- Dual Focus
- Responsive Insertion Technology
Dual Focus
Dual Focus is a unique OLYMPUS innovation. It uses a two-stage optical system.
This allows the user to switch between two focus settings. With a simple push of a button, you can choose the observation mode you want. Select “near mode” for amazing detail in close mucosal observation, or “normal mode” for regular observation.
Even in “normal mode”, EVIS EXERA III endoscopes feature an advanced level of resolving power compared to previous generations. With dual focus, Olympus is helping to revolutionise routine endoscopy.
Brighter and higher contrast Narrow Band Imaging
NBI in EVIS EXERA III offers a significantly increased viewable distance compared to previous generations. The better contrast and increased brightness mean that NBI helps you find and understand lesions more easily.
Unique Responsive Insertion Technology (RIT)
RIT combines three unique proprietary OLYMPUS technologies: HFT (High-Force Transmission), PB (Passive Bending) and Variable Stiffness. These technologies improve endoscope insertability and ergonomics. Thanks to RIT, the endoscope offers improved operator control when manoeuvring and moves more easily through the colon.
Improved image quality
EVIS EXERA III endoscopes provide top-quality images. They ensure great color and even brightness throughout the image. This is crucial for making a diagnosis. Thanks to improved signal processing, EVIS EXERA III endoscopes feature significantly reduced levels of halation and noise.
ScopeGuide compatibility
Olympus CF-HQ190L has ScopeGuide compatibility as a standard feature. This lets you see its position inside the colon using a 3D image on the monitor.
Using ScopeGuide helps find and remove insertion tube loops. This can increase caecal intubation rates. It also reduces procedure times and patient pain. Since ScopeGuide does not use X-rays, you can use it continually throughout the procedure.
170°Field of View
The top-quality field of view lets you see behind the folds in the colon. This reduces the need to adjust the endoscope’s angulation controls.
Waterproof One-touch Connector
EVIS EXERA III endoscopes have a new connector design. This design does not need a video or ScopeGuide cable. The connector is fully submersible, eliminating the need for a water-resistant cap.
Designed for ease-of-use
Ergonomically designed control section for enhanced colonoscope maneuverability, with easy-to-access controls and user-programmable switches.
The EVIS EXERA III Videocolonoscope Olympus CF-HQ190L revolutionizes routine endoscopy by providing ground-breaking advanced diagnostic features in an easy-to-use routine endoscope. The device has many extra features.
One of these is Responsive Insertion Technology (RIT). This technology makes it easier to handle the scope. It facilitates insertion and may help reduce patient pain.
The EVIS EXERA III Videocolonoscope Olympus CF-HQ190L is at the forefront of Olympus endoscopy technology. The CF-HQ190 combines features like Dual Focus and brighter Narrow Band Imaging. This makes it a powerful diagnostic tool in a regular endoscope.
The endoscope has advanced diagnostic features. It also has ergonomic improvements. These changes make it easier to handle during the whole workflow.
Olympus CF-HQ190L Specifications:
- Field of View: 170 degrees (normal), 160 degrees (near)
- Depth of Field: 5 to 100 millimeters (normal), 2 to 6 millimeters (near)
- Distal End Outer Diameter: 13.2 millimeters
- Insertion Tube Outer Diameter: 12.8 millimeters
- Angulation Angle: 180 degrees (up, down), 160 degrees (right, left)
- Inner Diameter: 3.7 millimeters
- Minimum Visible Distance: 4 millimeters from distal end
- Working Length: 66.14 inches, 52.36 inches
- Total Length: 78.94 inches, 65.16 inches
Reference